FitXref / Well Pump / Square D part numbers

SQUARE D PART NUMBERS

Square D pressure switch part numbers, decoded.

On a 9013FSG2J21, 9013 is the class, FSG is a standard Pumptrol with an adjustable differential in a NEMA 1 enclosure, 2 is a 1/4" NPSF internal pipe connection, and J21 is the factory setting: 30/50 psi. J24 means 40/60 psi and J20 means 20/40 psi. Letters after the pressure code are options, such as M4 (low-pressure cut-off) or M1 (manual on/off lever).

Reference only. This page decodes the printed part number so you can compare switches. It is not a wiring, installation or pump-sizing approval: a pressure switch carries line voltage, so replacement should be done or checked by a licensed electrician or well professional.

Reading 9013FSG2J21 field by field

Square D part number fields (Square D document RP19080108)
FieldIn 9013FSG2J21What it means
Class9013Square D Pumptrol pressure switch family
TypeFSGS = standard, adjustable differential. T = non-adjustable differential. Y = higher HP, adjustable differential. R = reverse action.
EnclosureFSGG = NEMA 1. W = NEMA 3R (so a 9013FSW is the 3R version; Square D notes it must be mounted vertically to keep the 3R rating).
Fluid connection21 = 1/8" NPSF internal, 2 = 1/4" NPSF internal, 9 = 1/4" NPT external, 10 = 1/4" barbed bayonet, 20 = 90° elbow 1/4" bayonet. 42 and 49 are narrow-differential versions on the 2 and 9 connections (on the FSG: cut-out 9–30 psi, cut-in 3–10 psi; other types are listed with different ranges).
Pressure codeJ21Factory setting, cut-in/cut-out: 30/50 psi (see the full code list below)
Forms (options)noneExtra letters at the end, such as M1, M4, P or Z22 (see below)

Pressure codes

Square D pressure codes for the 9013FSG (2007 Square D catalog)
CodeFactory setting
J155–21 psi
J168–20 psi
J2020–40 psi
J1820–50 psi
J2130–50 psi
J2440–60 psi
J3350–70 psi
J3455–85 psi
J2560–80 psi
J99Pressure settings specified on the order

Square D notes that a code existing in the list "does not imply that the code is available for any or all devices": the setting has to fall inside the limits of the specific switch type. For a standard 9013FSG2, those limits are in the next section: J33, J34 and J25 have cut-outs above its 65 psi top, and J16's 12 psi differential is below its 15 psi minimum.

What a 9013FSG2 can be set to

9013FSG2 (1/4" NPSF) listed limits, 2007 Square D catalog
Cut-out (adjustable)20–65 psi
Cut-in (adjustable)5–45 psi
Differential (cut-out minus cut-in)15–30 psi
Maximum permissible pressure65 psi
Repeat accuracy±3% of the range

Versions with the M4 low-pressure cut-off (below) are listed separately, with a narrower range: cut-out 34–65 psi, cut-in 19–45 psi, differential 15–30 psi.

So a J21 (30/50) and a J24 (40/60) are the same switch body with different factory settings, and either can be adjusted within these limits. A target like 50/70 is outside them: the cut-out tops out at 65 psi. Square D also says system pressure should never exceed the upper limit of the range in normal operation, because it greatly reduces diaphragm life. To change settings on an adjustable switch, see the adjustment guide.

Option letters you'll see at the end

Common 9013FSG form letters (Square D catalog and RP19080108)
LetterMeaning
M1Maintained manual cut-off lever (AUTO / OFF)
M4Low-pressure cut-off (AUTO / START / OFF): opens the contacts at about 10 psi below cut-in and turns the pump off
PPulsation plug, for surges from high-speed jet pumps or fast-closing valves
QSalt-water metal flange (1/4" NPSF internal only)
Q8Plastic flange, 1/4" NPSF internal only (max. 120 °F, max. 80 psi)
T / T11/2" conduit bushing on the left / on the right
U / U2Slip-on connections on the load terminals only / on line and load terminals
Z22Black cover

The one that matters most for a homeowner is M4. A 9013FSG2J21M4 is a 30/50 switch that also shuts the pump off when pressure falls about 10 psi below cut-in. Square D gives a low-water condition as the example of why system pressure would be lost. Its lever is marked AUTO, START and OFF. If your old switch has M4 and the new one doesn't, you lose that shut-off. If a pump with an M4 switch "won't turn on", see the troubleshooting guide.

Motor size limits

Maximum single-phase motor the switch can control directly (2007 Square D catalog)
Type115 V230 V
9013FSG / FSW1.5 HP2 HP
9013FTG1 HP1 HP
9013FYG2 HP3 HP

Square D positions the FYG for larger pumps, and says its higher-HP switches can also run the control circuit of a magnetic starter for pumps bigger than they control directly. Whether that applies to your pump is an electrician's call.

Matching a replacement

Compare the old switch's number field by field: the type letter (S, T or Y), the enclosure letter (G or W), the full fluid connection code, the pressure code, and any option letters. Watch for 42 or 49 in the connection position: those are narrow-differential switches (a 9013FSG42 or FSG49 is listed at cut-out 9–30 psi, cut-in 3–10 psi), not a standard 2 or 9. The pressure code only sets the starting point on an adjustable switch, but the type letter, connection and options are physical differences. If the label is unreadable, our well pump picker starts from your house and pump instead.

Common questions

What does J21 mean on a Square D pressure switch?

J21 is the pressure code for a 30/50 psi factory setting: the pump starts at 30 psi and stops at 50 psi. J24 is 40/60 psi and J20 is 20/40 psi.

What is the difference between 9013FSG2J21 and 9013FSG2J24?

Only the factory setting: J21 ships at 30/50 psi and J24 at 40/60 psi. Both are 9013FSG2 switches with a 1/4" NPSF connection, an adjustable differential and the same listed limits (cut-out 20 to 65 psi; versions with the M4 option are listed at 34 to 65 psi).

What does M4 mean on a Square D pressure switch?

M4 is the low-pressure cut-off option. Square D says it opens the contacts at about 10 psi below cut-in and turns the pump off; its lever is marked AUTO, START and OFF.

Can a 9013FSG2 be set higher than 40/60?

Only within its listed limits. Square D lists the 9013FSG2 cut-out as adjustable from 20 to 65 psi with a 15 to 30 psi differential, so a setting such as 50/70 is outside what that switch is listed for.

Shop by setting

Match the type letter, enclosure letter, connection code and option letters of your old switch before you buy.

Pressure switch, 30/50 psi

The J21 factory setting: cut-in 30, cut-out 50.

Link coming soon
Pressure switch, 40/60 psi

The J24 factory setting: cut-in 40, cut-out 60.

Link coming soon